Dual channel monitor for the continuous measurement of pH and Redox (ORP) potential in pool water.
Complete system mounted on PVC panel including:
For use with (order seperately):
Optional accesory:
| pH Measurement with Swansensor pH Standard | |
| Measuring range | pH 1 to 13 |
| Resolution | 0.01 pH |
| Reference temperature | 25° C |
| Automatic temperature compensation according to Nernst. | |
| ORP (Redox) measurement with Swansensor Redox Standard | |
| Measuring range | -400 to 1'200 mV |
| Resolution | 1 mV |
| Temperature measurement with Swansensor Temperature Standard | |
| Measuring range | -30 to 130°C |
| Resolution | 0.1° C |
| Power Supply | |
| Voltage |
100-240 VAC (+- 10%), 50/60 Hz (+- 5%) or |
| Sample conditions | |
| Flow rate | min. 30 l/h |
| Temperature | up to 50° C |
| Inlet-, Outlet pressure | 0.2 to 2 bar |
| Dimensions | |
| Panel | 300 x 530 x 150 mm |